Navcon Engineering Vibration Control - Tuned Damper


In a recent project, Navcon & Halvorsen engineers encountered a 18 Hz resonance problem in a Drive Motor System. Various vibration control measures were investigated. Based upon the results of a sensitivity analysis it was determined that the optimal solution would be the installation of a tuned vibration damper. The following Graphs show the Frequency Response (Left) and the Operating Vibration Spectra (Right) recorded both without (Red) and with (Blue) the production Tuned Damper. The Drive Motor operates between 0 Hz. and 40 Hz. The vibration response of the Drive Motor System at 18 Hz was reduces by a factor of four (4).
FRF with and without tuned vibration damper Measured vibration response with and without tuned vibration damper
To open or download a 131 Kbytes PDF file containing a more complete description of this project click here, DraglineYou can view the file with Adobe Acrobat running on either a PC or Macintosh.   The PDF file can also be viewed in Web browsers using the Acrobat Reader 3.0 plug-in.  Please give us a call if you have problems downloading the file.

 